Search     
< Marsh Bellofram Group of Companies < Automatic Timing & Controls < Counter < 366B Series
Downloadable Files:
PDF icon 366B Series
366B Series Long-Ranger Computing Counter
  • Industry Standard Counter
  • Contact Bounce and Noise Immunity
  • Programmable Display
  • Wide Range of Counts
  • Compact, Plug-In and Dust Tight
Product Detail:
Based on a powerful built-in microcomputer, the compact 366B is the most versatile and cost-effective counter ATC has ever built. No industrial counter has ever achieved a higher level of reliability and ruggedness than the 366B. It has no moving parts in its electronic logic circuits, only plug-in circuit boards which are computer-tested for reliability and assembled virtually without hand wiring. Its few mechanical components have been selected for reliable service; long life relays with heavy-duty contacts and rotary set point selector switches with extremely low wear characteristics.
CONTACT BOUNCE AND NOISE IMMUNITY: No industrial counter offers greater immunity to noise and contact bounce than the 366B. Most noise encountered in typical industrial environments is blocked by such design features as full-wave bridges and a transformer power supply... so effectively that the 366B does not have to be shielded. Furthermore the 366B’s microcomputer employs redundant sampling logic to detect and reject any noise pulse that manages to penetrate its defenses. Through the same powerful technique, the microcomputer also detects and rejects even severe contact bounce. As a result, the 366B maintains absolute count accuracy and is virtually immune to false starts and reset, even in difficult industrial environments.
COMPUTATION: Through its internal microcomputer, the 366B keeps track of the set point throughout the count cycle. Whenever there is a change in set point, even during a cycle, it instantly recomputes the remaining count and accurately determines the number of counts before count-out. This unique capability is especially valuable in the count-down modes as it allows you to shorten or lengthen a cycle without loss of accuracy.
PROGRAMMABLE DISPLAY: The 366B’s three-digit cycle progress display will count UP to or DOWN from the set point, depending on the position of an internal jumper. After count-out, the display will either STOP or GO. In the UP & GO program, the display counts up to the set point and continues to count after count-out; in the DOWN & GO mode, it counts down to the set point, then begins to count up (from zero) after count-out.
WIDE RANGE: Each 366B Long-Ranger covers the overall span of 1 to 99,900 counts in three switch-selected ranges of 1 to 999, 10 to 9990 or 100 to 99,900. It can be optimized within any selected range simply by removing appropriate selector knobs (e.g. with the counter in the 1 to 999 range, you can obtain a tamper-proof span of 1 to 99 by setting the left selector at 0 and removing the knob.) To the right of the three-digit display, a counting bar () blinks on each time a pulse is received. At left, a marker turns on when the delayed relay is energized at count-out.
SELF-DIAGNOSTICS: A built-in diagnostic program lets you verify--without using any test instrument--that the counter’s functional circuits are operating properly. Just follow the instructions on the flip-up card, using the counter’s own display for the test readout. If all self-test displays are correct, any malfunction is almost certainly due to external circuits or to the relays, not the counter.
COMPACT, PLUG-IN AND DUST-TIGHT:
Packaged in a 72mm2 DIN housing, the 366B occupies 40% less panel space than most other industrial counters. It is a true plug-in counter that can be replaced in seconds without disturbing housing or wiring. The 366B is also fully gasketed and O ring sealed to be dust and water-tight whether panel or surface-mounted.
POSITIVE RESET TIME AND PULSE LENGTH: Digitally clocked by the microcomputer, the 366B’s reset time is consistently of the same duration, regardless of variations in line voltage, power supply or cycle length. When the 366B operates in repeat-cycle mode, the output pulse is also digitally clocked so that both the time of occurrence and its duration are consistent from cycle to cycle.
Part Numbers:
Create Model Number >>>>>
366B
xx
xx
xx
P
xx
Range
400
Q
30
P
X
19999, 10-9990 or 100-99900 (switch selected)
Special
000
Voltage & Frequency
120, 50/60 Hz
240, 50/60 Hz
R
24 VAC, 50 or 60 Hz
R
24 VDC
N
Special
K
Arrangement
Selectable Count Up or Count Down with Display
Selectable Count Up & Go or Count Down & Go with Display
50
Features
Basic plug-in unit
Standard Unit
Options:
Accessories
0353-260-27-00 Surface mounting bracket kit
0305-265-61-70 Retrofit kit
Purchase Details:
Product Contact:
Specifications:
Models Display model only for operation at 120, 240 or 24 VAC; and 24 VDC. Unit counts on break (i.e. when count input switch opens). Unit operates in on delay mode only.
Range Switch-selectable ranges of 1 to 999, 10 to 9990, and 100 to 99900
Repeat Accuracy 100% (+0 count on all ranges)
Reset Time Clocked at 40 mSec
Count Input Characteristics AC
Max.
count rate
1000/min. (symmetrical input)
Min. pulse on time 20 mSec
Min. pulse off time 30 mSec
DC
Max. count rate 2000/min. (symmetrical input)
Min. Pulse on time 15 mSec
Min. Pulse off time 15 mSec
Bounce Immunity (max. bounce open time) 5 mSec
Pulse Contact Req. 10 mA at line voltage
Count Control Modes Single Cycle interval or delayed
Repeat Cycle pulse (occurrence and duration 50 mSec clocked)
Display Cycle Progress 3-digit display, 0.3 inch, high-intensity, blue programmable modes: DOWN & STOP, DOWN & GO, UP & STOP or UP & GO.
Count-Out display; energized at count-out
Counting Bar display; blinks on when count switch is closed, when pulse is received
Housing 72mm2 DIN size; plug-in design; fully gasketed, dust and water-tight in panel mounted installations. NEMA 4 when mounted per installation instructions.
Terminals 16 screw terminals accessible at rear; integral wiring diagram.
Count Input (terminal 15) Voltage Model
120 VAC Model Turn On 60V  3.5 mA (nom.)
Turn Off 30V 2.4 mA (nom.)
10 mA max. current at 120V
240 VAC Model Turn On 120V  3.5 mA (nom.)
Turn Off 60V  2.4 mA (nom.)
10 mA max. current at 240V
24 VAC Model Turn On 12V  9.5mA (nom.)
Turn Off 4V 3.8 mA (nom.)
30 mA max. current at 24V
24 VDC Model Turn On 15 VDC 2.5 mA (nom.)
Turn Off 3 VDC .5 mA (nom.)
5 mA max. current at 24V
Load Relay Number one instantaneous and one delayed
Type DPDT, Form C
Operate Time 13 mSec, max.
Release Time 10 mSec, max.
Contact Ratings 7A at 120, 240 or 24 VAC, 1/6 HP. 3A at 24 VDC, 1.5A at 48 VDC, 0.5A at 125 VDC.
LIFE 100 million operations (no load)
Power Requirements 120V 95 to 132V, 50/60 Hz
inrush–0.3A
running–0.06A at 120 VAC
240V 190 to 264V, 50/60 Hz
inrush–0.15A
running–0.03A at 240 VAC
24 VAC 19.2 - 26.4 VAC, 50 or 60 Hz
Inrush–1 A
Running–0.25 A at 24 VAC
24 VDC 19.2 - 26.4 VDC, 5% ripple
Running - .120 A at 24 VDC
Temperature Rating 32 to 140°F (0 to 60°C)
Mounting Accessories Standard hardware is provided for front-of-panel mounting.
Optional Surface-mounting brackets with front-facing terminals
NEMA 12 molded case (1 counter)
NEMA 1 steel case (2 counters)